SNIP-05: Relay-to-Relays Control

covers21105

⚡tephen

published

draft optional

This SNIP defines kind:21105: an ephemeral command event used to trigger physical hardware relays (switches, solenoids, mag-locks) via software relays (Nostr).

Motivation

The term "relay" is overloaded.

  1. Software Relay: A WebSocket server that stores and forwards Nostr events.
  2. Hardware Relay: An electromechanical switch used to control high power circuits with low power signals.

SNIP-05 creates a bridge between the two, allowing a Nostr event to physically "click" a switch in the real world. This enables decentralized, cryptographically secure access control (e.g., opening a door) without relying on centralized IoT clouds.


Event Kind

  • 21105 — Ephemeral Command. These events are not stored long-term by the software relay; they are "fire and forget" instructions intended for immediate processing by the hardware client.

Tags

  • p — Target Device Pubkey. The public key of the hardware controller (e.g., the Raspberry Pi or ESP32 controlling the door).
  • d — Hardware ID. The specific pin, channel, or physical relay identifier on the device (e.g., "front_door", "relay_1", "garage").
  • cmd — Instruction. The action to perform. MUST be one of: "on", "off", "toggle", "pulse".
  • expiration — Security Timeout. Unix timestamp after which this command is invalid. CRITICAL for preventing replay attacks.

Content

The .content field is optional and may contain a human-readable message, e.g., "Open sesame".


Security & Replay Prevention

Hardware clients listening for kind:21105 MUST enforce the following rules:

  • Allowlist: The event author (.pubkey) MUST be in the device's authorized user list.
  • Freshness: The event created_at timestamp MUST be within a strict window (e.g., +/- 5 seconds) of the device's current time.
  • Expiration: If the "expiration" tag is present, the current time MUST be less than the expiration.
  • Idempotency: The device SHOULD cache the event .id of processed commands for a short duration to prevent processing the same "Unlock" command twice.

Example Workflow

  • User stands in front of their office door.
  • User taps "Unlock" in their Nostr client.
  • Client publishes kind:21105 to the specified software relay.
  • Hardware Controller (listening to the same software relay) sees the event.
  • Hardware Controller verifies the signature, checks the timestamp, and fires the physical solenoid.
  • Click. Door opens.

Example Event

{
  "kind": 21105,
  "id": "5561bd0f8e0417c3edaf89e7099e86debc00467d0ce7f92b910f90df9228e27a",
  "pubkey": "79be667ef9dcbbac55a06295ce870b07029bfcdb2dce28d959f2815b16f81798",
  "created_at": 1765150322,
  "tags": [
    [
      "d",
      "gate_01"
    ],
    [
      "cmd",
      "pulse"
    ]
  ],
  "content": "",
  "sig": "c8c6687cd8a9d127c309b7cb131f3fa42251bba5c2767a7faab8c45e80b9f7b86ed0fc92566d3d367b77f53237be41bcf88a004d3793a822671a468ad7ac0248"
}

Why "Pulse"?

For electromechanical locks (mag-locks or door strikes), you typically don't want "On" (unlock forever) or "Off" (lock). You want a Pulse (Unlock for 5 seconds, then auto-lock). This logic is handled by the hardware client when receiving the pulse command.

Discussion

Connect a key to comment.